CHIPER
Submersible sewage pump

Submersible sewage pump that is widely used in crafts and industry to evacuate clean or dirty water or other liquids.

The unit can lift fluids from rainwater storage tanks or traps, from basements, for drying subways or other uses.

Description

Description

  • Submersible sewage pump that is widely used in crafts and industry to evacuate clean or dirty water or other liquids. The unit can lift fluids from rainwater storage tanks or traps, from basements, for drying subways or other uses.
  • Equipped with an opened vortex impeller (VRX) or a double-channel opened impeller (BC), depending on the model.
  • The components have been precisely selected for maximum reliability and long service life even in the toughest applications.
  • Not suitable for lifting combustible fluids. It is also forbidden to position or to remove the pump by means of the electric cable.

¡Take a closer look at our other submersible pumps!


Materials

 Pump casing GG-20 cast iron
 Impeller GG-20 cast iron
 Motor casing GG-20 cast iron
 Motor-pump shaft 416 SS
 Mechanical seal Silicon carbide/alumina
 Gaskets Nitrile rubber

 

Technical data

 Motor Single-phase or three-phase depending on the model
 Tension Single-phase 230 V ± 5% up to 2 HP
Three-phase 230/400 V ± 5% up to 5,5 HP
 Poles 2
 Level of protection IP68
 Insulation F Class

 

Usage limits

 Range of flow rates Up to 975 l/min depending on the model
 Range of pressures Up to 1,9 bar depending on the model
 Max. Working pressure 4 bar
 Max. Working temperature (continuous duty) 60ºC
 Max. Working temperature (intermittent duty) Up to 90ºC
 Minimum pumping level 10 cm above the pump casing
 Maximum flui density Not exceeding 1100 kg/m3