﻿{"id":12999,"date":"2018-05-14T10:00:41","date_gmt":"2018-05-14T10:00:41","guid":{"rendered":"https:\/\/elias.es\/producto\/ft-bomba-centrifuga-alta-temperatura-iso2858\/"},"modified":"2025-09-23T11:13:23","modified_gmt":"2025-09-23T11:13:23","slug":"iso-2858-standardized-centrifugal-pump-for-heat-transfer-fluid","status":"publish","type":"product","link":"https:\/\/elias.es\/en\/product\/iso-2858-standardized-centrifugal-pump-for-heat-transfer-fluid\/","title":{"rendered":"FT<br>ISO 2858 standardized centrifugal pump for heat transfer fluid (350\u00baC)"},"content":{"rendered":"<h4>Description<\/h4>\n<ul>\n<li><strong>ISO 2858 standardized centrifugal pump for heat transfer fluid (350\u00baC).<\/strong><\/li>\n<li>It is suitable for any <strong>heat transfer fluid<\/strong> application in industry up to temperatures of <strong>350\u00baC<\/strong>. It is also appropriate for other high temperature applications with other types of fluids, such as superheated water.<\/li>\n<li><span style=\"text-decoration: underline;\">Versions available:<\/span>\n<ul>\n<li><strong>EL-Bare Shaft<\/strong> version with no motor attached.<\/li>\n<li><strong>SB-On Basepalte<\/strong> version with motor coupled to the pump by simple elastic coupling or with spacer, for a <em><strong><span style=\"text-decoration: underline;\"><a href=\"https:\/\/empoweringpumps.com\/heinz-bloch-uptime-reliability-back-pull-out-pumps\/\">Back Pull-out <\/a><\/span><\/strong>system<\/em>, that facilitates maintenance and cleaning of the unit.<\/li>\n<\/ul>\n<\/li>\n<li><a href=\"https:\/\/elias.es\/download\/12743\/?tmstv=1708601578\"><span style=\"text-decoration: underline;\">NV-2 Type<\/span><\/a> mechanical seal , according to EN12756 standards, with independent direction of rotation.<\/li>\n<li>A <strong>finned heatsink casing<\/strong> has been designed to considerably reduce the working temperature of the pump in the area of the mechanical seal and bearings, ensuring their optimum performance and extending the useful life of the assembly.<\/li>\n<li>It incorporates an<strong> oil-lubricated bearing housing<\/strong> away from the high temperature zone, and incorporates a <strong>front bearing<\/strong> that acts as a restrictive ring and also provides stability to the assembly.<\/li>\n<li>Possibility of installation in explosive atmosphere in accordance with <strong>ATEX<\/strong> directives.<\/li>\n<\/ul>\n<hr \/>\n<h3><span style=\"color: #0b2065;\">Take a look at all our solutions for <a href=\"https:\/\/elias.es\/en\/sectors-industry\/\"><span style=\"text-decoration: underline;\">HEAT TRANSFER FLUID<\/span><\/a> installations!<\/span><\/h3>\n<hr \/>\n<h4>Materials<\/h4>\n<table style=\"height: 149px; width: 62.8823%; border-color: #ededed; border-collapse: collapse; background-color: #f6f6f6; border-style: dashed;\">\n<tbody>\n<tr style=\"height: 29px;\">\n<td style=\"width: 35.6658%; height: 29px;\">\u00a0Pump casing<\/td>\n<td style=\"width: 87.072%; height: 29px;\">GGG-40 ductile cast iron<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 35.6658%; height: 24px;\">\u00a0Impeller<\/td>\n<td style=\"width: 87.072%; height: 24px;\">GG-20 cast iron<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 35.6658%; height: 24px;\">\u00a0Pump shaft<\/td>\n<td style=\"width: 87.072%; height: 24px;\">AISI 420<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 35.6658%; height: 24px;\">\u00a0Heatsink casing<\/td>\n<td style=\"width: 87.072%; height: 24px;\">GGG-40 ductile cast iron<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 35.6658%; height: 24px;\">\u00a0Mechanical seal<\/td>\n<td style=\"width: 87.072%; height: 24px;\">NV-2 Type (EN 12756)<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 35.6658%; height: 24px;\">\u00a0Bearings<\/td>\n<td style=\"width: 87.072%; height: 24px;\">Standard deep groove ball bearings<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Technical data<\/h4>\n<table style=\"height: 149px; width: 73.3436%; border-collapse: collapse; border-style: dashed; border-color: #ededed; background-color: #f6f6f6;\">\n<tbody>\n<tr style=\"height: 29px;\">\n<td style=\"width: 31.4912%; height: 29px;\">\u00a0Motor<\/td>\n<td style=\"width: 51.0402%; height: 29px;\">Three-phase according to IEC standards<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 31.4912%; height: 24px;\">\u00a0Efficiency<\/td>\n<td style=\"width: 51.0402%; height: 24px;\">IE2 or IE3 for power &gt; 1 HP<br \/>\nIE1 if the power &lt; 1 HP<br \/>\nIt can be supplied up to IE5.<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 31.4912%; height: 24px;\">\u00a0Tension<\/td>\n<td style=\"width: 51.0402%; height: 24px;\">Three-phase 230\/400 V \u00b1 10% up to 5.5 HP<br \/>\nThree-phase 400\/690 V \u00b1 10% from 7.5 HP upwards<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 31.4912%; height: 24px;\">\u00a0Poles<\/td>\n<td style=\"width: 51.0402%; height: 24px;\">2 or 4 depending on the model<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 31.4912%; height: 24px;\">\u00a0Level of protection<\/td>\n<td style=\"width: 51.0402%; height: 24px;\">IP55<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 31.4912%; height: 24px;\">\u00a0Insulation<\/td>\n<td style=\"width: 51.0402%; height: 24px;\">F Class<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h4>Usage limits<\/h4>\n<table style=\"border-style: dotted; border-color: #ededed; height: 149px; width: 78.0377%; border-collapse: collapse; background-color: #f6f6f6;\">\n<tbody>\n<tr style=\"height: 29px;\">\n<td style=\"width: 40.2579%; height: 29px;\">\u00a0Range of flow rates<\/td>\n<td style=\"width: 84.3582%; height: 29px;\">\u00a0Up to 210 m<sup>3<\/sup>\/h depending on the model<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 40.2579%; height: 24px;\">\u00a0Range of pressures<\/td>\n<td style=\"width: 84.3582%; height: 24px;\">\u00a0Up to 10 bar depending on the model<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 40.2579%; height: 24px;\">\u00a0Max. Working pressure<\/td>\n<td style=\"width: 84.3582%; height: 24px;\">\u00a016 bar<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 40.2579%; height: 24px;\">\u00a0Max. Working temperature<\/td>\n<td style=\"width: 84.3582%; height: 24px;\">\u00a0350\u00baC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>ISO 2858 standardized centrifugal pump for heat transfer fluid installations in the industry sector up to temperatures of 350\u00baC.<\/p>\n<p>The unit equips an NV-2 Type mechanical seal. It also incorporates an oil-lubricated bearing bracket.<\/p>\n","protected":false},"featured_media":11167,"template":"","meta":[],"product_brand":[],"product_cat":[746],"product_tag":[775,781,785],"class_list":["post-12999","product","type-product","status-publish","has-post-thumbnail","product_cat-centrifugal-pumps","product_tag-atex-en","product_tag-en22858-iso2858-en","product_tag-on-baseplate-pumps","first","instock","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/product\/12999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/media\/11167"}],"wp:attachment":[{"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/media?parent=12999"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/product_brand?post=12999"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/product_cat?post=12999"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/elias.es\/en\/wp-json\/wp\/v2\/product_tag?post=12999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}